ENERGIRAN has a successful background of construction and installation for the packages and equipment which to be installed at site such as storage tanks, air cooled heat exchangers and most of process units and packages.
For instance ENERGIRAN Storage tank construction process is divided into semi precast and on-site installation of two parts.
Semi-finished products: the bottom of the tank, the tank wall prefabricated, tank top and other components are prefabricated
On the spot installation method: divided into flip chip construction technology, construction technology and special formal construction technology.
All required considerations are mentioned in ENERGIRAN installation & operation manual such as foundation design and construction process, excavation of foundation pit, Reinforced concrete, Earthwork backfilling and compaction of backfill soil, sand blast, and Slope protection construction.
For the tubular heat exchanger ENERGIRAN installation position required may be used for venting and draining via the connecting branches. ENERGIRAN installation team makes sure that the heat exchanger is properly vented when filling it. ENERGIRAN team, install all the connecting piping and any supports that may be required so that an unobstructed heat expansion of the heat exchanger is ensured by ENERGIRAN installation team.
ENERGIRAN Installation group consider the position for heat exchangers with steam as internal medium. The installation position should preferably be such that the tubes are arranged vertically. ENERGIRAN installation team makes sure that the tubes may expand as described above. If the heat exchanger is designed for horizontal installation, it will be constructed so that the tubes are inclined towards the condensate side, or the heat exchanger must be installed with such an inclination of the tubes (about 2°). If the system works with condensate depression, ENERGIRAN provides a separate condensate depression device in the downstream of the steam operated heat exchanger.
- All the equipment and units supplied by ENERGIRAN will be installed by qualified personnel who have solid understanding of system design, pressure and temperature ratings, and piping assembly.
- The service conditions of the system prior to applying any shell & tube heat exchanger are verifies.
- The installation plan would be executed to meet the requirements indicated on the piping installation diagram as client’s specification.
- The indicated port assembly sequence in the ENERGIRAN diagram maximizes the performance, and minimizes the possibility of thermal shock. In instances where the fluids are required to be reversed, hot fluid in the tubes and cold fluid in the shell the heat exchanger will work with reduced performance.